噴涂行業(yè)是揮發(fā)性有機物(VOC)排放大戶,用固體吸附管采集VOC,熱解析前處理方式,應(yīng)用氣相色譜/質(zhì)譜儀對VOC進行分離分析.結(jié)果證明,固體吸附管采集-熱解析-氣相色譜/質(zhì)譜法分析噴涂行業(yè)中的揮發(fā)性有機物具有很好的效果,結(jié)果看出噴涂行業(yè)VOC排放量較大,其中80%以上為苯系物,在面漆和烘干車間體現(xiàn)的較為明顯.
?
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司,研制《TA復(fù)合吸附管應(yīng)用安捷倫》
,制藥工業(yè)中測定VOCs的常用方法包括吸附采樣結(jié)合氣相色譜法,該方法通過Tenax-TA或復(fù)合吸附管采集空氣樣本,
再經(jīng)熱解吸處理后用氣相色譜儀分析,能夠準(zhǔn)確分離和定量各種揮發(fā)性有機物,結(jié)果滿意。
?
名稱:吸附管
填料:TA+石墨化炭黑+碳分子篩
材質(zhì):硅烷化不銹鋼管
尺寸:25cm*1/8
應(yīng)用:固定污染源廢氣中VOcs的測定
?
適用于:
安捷倫490在線/便攜,4890,5890,6890,7820,7890,8860,8890
島津GC-14C,GC-2010,GC-2014,GC-2030
賽默飛1310,1300,1610,1600
瓦里安3800系列
布魯克PE580,590,680,690
磐諾A90,福立GC9790,華愛,天瑞,天美,GC7900,川儀,北分瑞利,東西電子,魯南瑞虹,捷島/科曉
?


?
The spray coating industry is a major emitter of volatile organic compounds (VOCs). Solid adsorption tubes are used to collect VOCs, which are then subjected to thermal analysis pre-treatment. Gas chromatography/mass spectrometry is used to separate and analyze VOCs The results showed that solid adsorption tube collection thermal analysis gas chromatography/mass spectrometry had a good effect on analyzing volatile organic compounds in the spraying industry. The results showed that the VOC emissions in the spraying industry were relatively high, with more than 80% being benzene based compounds, which were more evident in the topcoat and drying workshops
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. is developing "TA Composite Adsorption Tube Application Agilent"
The commonly used methods for determining VOCs in the pharmaceutical industry include adsorption sampling combined with gas chromatography, which collects air samples through Tenax TA or composite adsorption tubes,
After thermal desorption treatment, various volatile organic compounds can be accurately separated and quantified using gas chromatography analysis, with satisfactory results.
Name: Adsorption Tube
Packing: TA+graphitized carbon black+carbon molecular sieve
Material: Silanized stainless steel pipe
Size: 25cm * 1/8
Application: Determination of VOCs in exhaust gas from fixed pollution sources
Suitable for:
Agilent 490 online/portable, 48905890689088608890
Shimadzu GC-14C, GC-2010, GC-2014, GC-2030
Thermo Fisher Scientific 1310130016101600
Varian 3800 Series
Brooke PE580590680690
Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao
滕州市浩瀚色譜儀器技術(shù)服務(wù)有限公司
電話:0632-5667636
傳真:0632-5667636
手機:15562228838,13963221227
地址:山東滕州市平行路(商務(wù)部和技術(shù)部)
郵箱:wangxiaoying9@126.com
QQ:1404939462
聯(lián)系人:王經(jīng)理
網(wǎng)址:tamasabel.com