国产午夜福利在线观看和下属_亚洲一区二区三区四_五月天亚洲天堂色图_国产国语三级级在线电影

聯(lián)系我們

 

聯(lián)系我們

浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
電話:0632-5667636
傳真:0632-5667636
手機(jī):15562228838,13963221227

地址:山東滕州市平行路(商務(wù)部和技術(shù)部)
郵箱:wangxiaoying9@126.com
QQ:1404939462
聯(lián)系人:王經(jīng)理
網(wǎng)址:tamasabel.com

GDX-101高分子小球應(yīng)用藥典2015四部0521
  • GDX-101高分子小球應(yīng)用藥典2015四部0521

  • 發(fā)布時(shí)間:2025-5-10 12:0:29
  • 產(chǎn)品簡介:
    型號:GDX-101填充柱
    規(guī)格:2m*3MM,60-80目
咨詢熱線:0632-5667636

應(yīng)用《中國藥典》2015年版四部通則0861殘留溶劑測定法對藥品中的殘留溶劑進(jìn)行測定.方法 以頭孢硫脒的殘留溶劑檢測為例,探討了在使用固定的殘留溶劑檢測方法不能有效測定樣品中的殘留溶劑時(shí),如何應(yīng)用《中國藥典》2015年版四部通則0861的方法測定樣品中的殘留溶劑.結(jié)果 應(yīng)用《中國藥典》2015年版通則0861殘留溶劑測定法,對不同生產(chǎn)廠家的頭孢硫脒中的殘留溶劑進(jìn)行了全面準(zhǔn)確的測定.結(jié)論 在固定的殘留溶劑測定方法不能準(zhǔn)確測定藥品中的殘留溶劑時(shí),應(yīng)用《中國藥典》2015年版通則0861中的雙柱定性方法可以快速、準(zhǔn)確地鑒別出藥品中未知的殘留溶劑,針對待測樣品建立準(zhǔn)確的殘留溶劑測定方法.

?

編號:20231124006
型號:GDX-101填充柱
規(guī)格:2m*3MM,60-80目
使用溫度:250°C
應(yīng)用: yao典2025年版四部0521,0861,溶劑殘留測定
適用于:島津,安捷倫,賽默飛,瓦里安,布魯克,PE等

5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱

?

The determination of residual solvents in drugs was carried out using the 0861 residual solvent detection method in the 2015 edition of the Chinese Pharmacopoeia. Taking the detection of residual solvents in ceftriaxone as an example, this study explored the effectiveness of using fixed residual solvent detection methods when residual solvents in samples cannot be effectively determined, How to apply the method specified in the 2015 edition of the Chinese Pharmacopoeia to determine residual solvents in samples? Results: The residual solvent determination method specified in the 2015 edition of the Chinese Pharmacopoeia was applied to comprehensively and accurately determine residual solvents in cephalosporin from different manufacturers. Conclusion: When fixed residual solvent determination methods cannot accurately determine residual solvents in drugs, The dual column qualitative method in the 2015 edition of the Chinese Pharmacopoeia General Rule 0861 can quickly and accurately identify unknown residual solvents in drugs, and establish an accurate residual solvent determination method for the test sample

Number: 20231124006

Model: GDX-101 filled column

Specification: 2m * 3MM, 60-80 mesh

Operating temperature: 250 ° C

Application: Yao Dian 2025 Edition Part 4 05210861, Solvent Residue Determination

Applicable to: Shimadzu, Agilent, Thermo Fisher, Varian, Brooke, PE, etc

聯(lián)系人
手機(jī)號碼
電子郵件
驗(yàn)證碼
看不清楚?點(diǎn)擊換張圖片
我要評論:

(內(nèi)容最多500個(gè)漢字,1000個(gè)字符)

驗(yàn) 證 碼 :
提交信息