国产午夜福利在线观看和下属_亚洲一区二区三区四_五月天亚洲天堂色图_国产国语三级级在线电影

聯(lián)系我們

 

聯(lián)系我們

浩瀚色譜(山東)應(yīng)用技術(shù)開(kāi)發(fā)有限公司
電話:0632-5667636
傳真:0632-5667636
手機(jī):15562228838,13963221227

地址:山東滕州市平行路(商務(wù)部和技術(shù)部)
郵箱:wangxiaoying9@126.com
QQ:1404939462
聯(lián)系人:王經(jīng)理
網(wǎng)址:tamasabel.com

中國(guó)藥典2015年版甲醇測(cè)定HQ填充柱
  • 中國(guó)藥典2015年版甲醇測(cè)定HQ填充柱

  • 發(fā)布時(shí)間:2025-5-10 11:57:26
  • 產(chǎn)品簡(jiǎn)介:
    中國(guó)藥典2015年版
    甲醇
咨詢熱線:0632-5667636

第二法(填充柱法)

色譜條件與系統(tǒng)適用性試驗(yàn) 用直徑為0.18~0.25mm的二乙烯苯-乙基乙烯苯型高分子多孔小球作為載體;柱溫125℃。理論板數(shù)按甲醇峰計(jì)算應(yīng)不低于1500;甲醇峰、乙醇峰與內(nèi)標(biāo)物質(zhì)各相鄰色譜峰之間的分離度應(yīng)符合規(guī)定。

校正因子測(cè)定 精密量取正丙醇1ml,置100ml量瓶中,用水溶解并稀釋至刻度,搖勻,作為內(nèi)標(biāo)溶液。另精密量取甲醇1ml,置100ml量瓶中,用水稀釋至刻度,搖勻,精密量取10ml,置100ml量瓶中,精密加入內(nèi)標(biāo)溶液10ml,用水稀釋至刻度,搖勻,取1μl注入氣相色譜儀,連續(xù)進(jìn)樣3~5次,測(cè)定峰面積,計(jì)算校正因子。

測(cè)定法 精密量取內(nèi)標(biāo)溶液1ml,置10ml量瓶中,加供試液至刻度,搖勻,作為供試品溶液,取lμl注入氣相色譜儀,測(cè)定,即得。

除另有規(guī)定外,供試液含甲醇量不得過(guò)0.05% (ml/ml)?。

?

編號(hào):20231007007
型號(hào):HQ填充柱
規(guī)格:2m*1/8,60-80目
*高使用溫度:200°C

?

5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱

?

Second method (filled column method)

Chromatographic conditions and system suitability tests were carried out using porous microspheres of divinylbenzene ethylenebenzene type polymers with a diameter of 0.18-0.25mm as carriers; The column temperature is 125 ℃. The number of theoretical plates calculated based on methanol peak should not be less than 1500; The resolution between the methanol peak, ethanol peak, and adjacent chromatographic peaks of the internal standard substance should comply with regulations.

Precision measurement of calibration factor: Take 1ml of n-propanol and place it in a 100ml volumetric flask. Dissolve and dilute with water to the mark, shake well, and use it as the internal standard solution. Accurately measure 1ml of methanol and place it in a 100ml volumetric flask. Dilute with water to the mark, shake well. Accurately measure 10ml and place it in a 100ml volumetric flask. Accurately add 10ml of internal standard solution and dilute with water to the mark, shake well, and take 1 μ Inject into the gas chromatograph, continuously inject 3-5 times, measure the peak area, and calculate the correction factor.

Precision measurement method: Take 1ml of the internal standard solution, place it in a 10ml volumetric flask, add the test solution to the mark, shake well, and use it as the test solution. Take l μ Inject into a gas chromatograph, measure, and obtain.

Unless otherwise specified, the methanol content of the test solution shall not exceed 0.05% (ml/ml).

No.: 20231007007

Model: HQ filled column

Specification: 2m * 1/8, 60-80 mesh

*High operating temperature: 200 ° C

聯(lián)系人
手機(jī)號(hào)碼
電子郵件
驗(yàn)證碼
看不清楚?點(diǎn)擊換張圖片
我要評(píng)論:

(內(nèi)容最多500個(gè)漢字,1000個(gè)字符)

驗(yàn) 證 碼 :
提交信息